TGuide S96 Ihe Nchọpụta Nucleic Acid na -akpaghị aka

Ọ dị oke elu ebe niile, na -ewepụta nlele 192 n'otu ọsọ.

TGuide S96 Nucleic Acid Extractor na -akpaghị aka na -anabata mgbasa ozi mkpanaka ndọta ọhụrụ ma nyefee usoro bekee magnet. A na-etinye efere olulu miri emi dị omimi 96 na ụdị ihe ndọta ndọta ndọta dị iche iche iji wepụta na hichaa nucleic acid site n'ọbara/sel/anụ ahụ/nje na ihe nlele ndị ọzọ 1-192.

Enwere ike ịnwe ihe nrụpụta ihe nwere modulu 24 nke nwere ezigbo mgbanwe maka nlele buru ibu. A kwadebere ya na reagents TIANGEN ebukọtara ọnụ ma nwee ike wepụta 1-24 n'otu oge. Oke kachasị nlele nke ngwaọrụ na -edozi bụ 5 ml. Ọ dabara nke ọma maka iwepụta acid nucleic n'efu na ọbara na plasma. O nwere mkpụrụ mmịpụta dị elu yana ịdị ọcha dị mma, enwere ike iji ya rụọ ọrụ dịka nchọpụta akpụ, NIPT, wdg.

Nwamba. Mba Nkwakọ ngwaahịa
OSE-S96-01 1 Nịm
OSE-S96-02 1 Tọọ
OSE-S96-03 1 Tọọ

Nkọwa ngwaahịa

Mkpado ngwaahịa

Oke ọrụ

Operating Parameters

Ụkpụrụ

Principle

Otutu nkwa nke Ultra High Nweta & Ọcha

Ọnọdụ mgbasa ozi mgbasa, arụmọrụ mgbake ndọta ≥ 98%
Site na ọnọdụ mgbasa mgbasa mgbasa yana ọsọ na -agbanwe agbanwe, a na -adọba okpu ndọta n'ọnụ ọnụ mkpanaka ndọta n'oge usoro ndọta nke na -agbada nwayọ nke mkpanaka magnetik, ka ọ bụrụ n'okpuru ọnọdụ na olu elution dị ntakịrị, onye dị elu ka nwere ike kpuchie magnetik niile. chaplet na igbasa ruo ọtụtụ oge, na ọbụna ndọta ndọta nwere obere urughuru nwere ike gbasaa nke ọma.

Operating Parameters  Operating Parameters   Principle Principle  Multiple Guarantees of Ultra High Yield & Purity  Circulation adsorption mode, magnetic bead recovery efficiency ≥ 98% Through the circulation adsorption mode with adjustable speed, magnetic beads are adsorbed on the tip of the magnetic rod during the slow descending process of the magnetic rod, so that under the condition that the elution volume is small, the eluent can still cover all the magnetic beads and circulate for many times, and even the magnetic beads with small particle sizes can be effectively adsorbed.       Four-Dimensional Integrated Motion Mode Ensures The Best Blending Effect ■ The four-dimensional integrated motion mode of X/Y/Z motion of the mechanical arm integral module and vibration of the mixing parts ensures stable operation and high precision of the instrument; ■ The instrument has high oscillation frequency and adjustable multi-gear, which is suitable for different reagent integration schemes; ■ The vibration amplitude can be adaptively adjusted according to the solution volume set by the user, thus achieving the best experimental mixing effect. Professional Pollution Control & Safety Guarantee ■ UV sterilization module: It can ensure that the operation in the machine reaches a sterile environment; ■ Anti-aerosol fan: Keep the air in the instrument in circulation to avoid aerosol pollution; ■ Anti-dripping disc: Effectively avoid cross contamination between wells and plates; ■ Closed operation: If the door is opened accidentally, the instrument will automatically pause to ensure safety; ■ Disposable reagent consumables: To protect the safety of laboratory personnel and laboratory environment to the greatest extent. Reasonable Design of The Expandable Throughout The matrix arrangement of double row and four plate positions not only ensures the expandability of the experiment, but also reduces the occupied area of the instrument and effectively uses the space. Under limited conditions, it can be expanded to extract 192 samples at a time, ensuring a ultra-high throughput extraction capability. With double heating modules of lysis/elution, the extraction efficiency can be improved.        Intuitive and User-Friendly Human-Computer Interaction Interface The 10.1-inch touch computer is equipped with Windows system and touch operation, which is simple and easy to use, conforming to the user’s usage habits. The program setting takes full account of the experimental expansibility, multi-parameter free configuration, and large integration and development space. Product Guide for TGuide S96  Features ■ Extremely high throughout: 192 samples can be extracted in a single run. ■ Operation mode: 10.1-inch touch interface (Windows system) ■ Magnetic bead adsorption: Cycle adsorption, recovery efficiency ≥ 98% ■ Movement mode: Four-dimensional integrated movement, confirming the best mixing effect ■ Replaceable modules: A 24-flux modules can be provided, with flexible processing volume ■ Professional contamination prevention: Effective avoidance of cross-contamination between wells and plates

Ọnọdụ mmegharị nke akụkụ anọ na-eme ka ọ pụta ìhè na-enwe mmetụta kacha agwakọta nke ọma

■ Ọnọdụ mmegharị agbakwunyere akụkụ anọ nke X/Y/Z ngagharị nke modul mebere ogwe aka na ịma jijiji nke ngwakọta ngwakọta na-eme ka arụ ọrụ kwụsiri ike na oke nke ngwa ahụ;
Ngwa ahụ nwere ugboro oscillation dị elu yana ọtụtụ igwe na-agbanwe agbanwe, nke dabara maka atụmatụ njikọta reagent dị iche iche;
■ Enwere ike ịhazigharị njupụta vibration dị ka olu olu nke onye ọrụ setịpụrụ, si otú a na -enweta nsonaazụ ngwakọta nnwale kacha mma.
Njikwa mmetọ ọkachamara & nkwa nchekwa
Module Modulu sterilization UV: Ọ nwere ike hụ na ọrụ igwe na -erute ebe adịghị mma;
Ihe na-emegide ihe na-emegide ikuku: Debe ikuku n'ime ihe na-ekesa iji zere mmetọ ikuku;
Disc Diski na-amịkọrọ mmiri: zere mmetọ obe n'etiti olulu mmiri na efere;
Operation Ọrụ emechiri emechi: Ọ bụrụ na emeghere ụzọ na mberede, akụrụngwa ga -akwụsịtụ na -akpaghị aka iji hụ na nchekwa;
Ihe mkpofu reagent enwere ike: Iji kpuchido nchekwa nke ndị ọrụ ụlọ nyocha na gburugburu ụlọ nyocha ruo oke.
Ezi Uche Design nke The Expandable Kemgbe ụwa
Nhazi matriks nke ahịrị abụọ na ọkwa efere anọ ọ bụghị naanị na -ahụ na ịgbasa nnwale ahụ, kamakwa ọ na -ebelata mpaghara akụrụngwa nwere ma na -eji ohere ahụ eme ihe nke ọma. N'okpuru ọnọdụ amachiri, enwere ike ịgbasa ya wepụta ihe nlele 192 n'otu oge, na-agba mbọ ikike iwepụta oke dị elu. Site na modulu kpo oku okpukpu abụọ nke lysis/elution, enwere ike melite arụmọrụ mmịpụta.

Operating Parameters  Operating Parameters   Principle Principle  Multiple Guarantees of Ultra High Yield & Purity  Circulation adsorption mode, magnetic bead recovery efficiency ≥ 98% Through the circulation adsorption mode with adjustable speed, magnetic beads are adsorbed on the tip of the magnetic rod during the slow descending process of the magnetic rod, so that under the condition that the elution volume is small, the eluent can still cover all the magnetic beads and circulate for many times, and even the magnetic beads with small particle sizes can be effectively adsorbed.       Four-Dimensional Integrated Motion Mode Ensures The Best Blending Effect ■ The four-dimensional integrated motion mode of X/Y/Z motion of the mechanical arm integral module and vibration of the mixing parts ensures stable operation and high precision of the instrument; ■ The instrument has high oscillation frequency and adjustable multi-gear, which is suitable for different reagent integration schemes; ■ The vibration amplitude can be adaptively adjusted according to the solution volume set by the user, thus achieving the best experimental mixing effect. Professional Pollution Control & Safety Guarantee ■ UV sterilization module: It can ensure that the operation in the machine reaches a sterile environment; ■ Anti-aerosol fan: Keep the air in the instrument in circulation to avoid aerosol pollution; ■ Anti-dripping disc: Effectively avoid cross contamination between wells and plates; ■ Closed operation: If the door is opened accidentally, the instrument will automatically pause to ensure safety; ■ Disposable reagent consumables: To protect the safety of laboratory personnel and laboratory environment to the greatest extent. Reasonable Design of The Expandable Throughout The matrix arrangement of double row and four plate positions not only ensures the expandability of the experiment, but also reduces the occupied area of the instrument and effectively uses the space. Under limited conditions, it can be expanded to extract 192 samples at a time, ensuring a ultra-high throughput extraction capability. With double heating modules of lysis/elution, the extraction efficiency can be improved.        Intuitive and User-Friendly Human-Computer Interaction Interface The 10.1-inch touch computer is equipped with Windows system and touch operation, which is simple and easy to use, conforming to the user’s usage habits. The program setting takes full account of the experimental expansibility, multi-parameter free configuration, and large integration and development space. Product Guide for TGuide S96  Features ■ Extremely high throughout: 192 samples can be extracted in a single run. ■ Operation mode: 10.1-inch touch interface (Windows system) ■ Magnetic bead adsorption: Cycle adsorption, recovery efficiency ≥ 98% ■ Movement mode: Four-dimensional integrated movement, confirming the best mixing effect ■ Replaceable modules: A 24-flux modules can be provided, with flexible processing volume ■ Professional contamination prevention: Effective avoidance of cross-contamination between wells and plates

Kensinammuo na onye ọrụ-enyi na enyi mmadụ-Kọmputa mmekọrịta
Ejiri kọmpụta mmetụ aka 10.1 nwere sistemụ Windows yana ọrụ mmetụ, nke dị mfe ma dị mfe iji, na-ekwekọ n'omume ojiji onye ọrụ. Ntọala mmemme ahụ na-ewere akaụntụ zuru oke gbasara nnwale nnwale, nhazi ọtụtụ ihe enweghị oke, yana nnukwu njikọta na oghere mmepe.

Ntụziaka ngwaahịa maka TGuide S96

Operating Parameters  Operating Parameters   Principle Principle  Multiple Guarantees of Ultra High Yield & Purity  Circulation adsorption mode, magnetic bead recovery efficiency ≥ 98% Through the circulation adsorption mode with adjustable speed, magnetic beads are adsorbed on the tip of the magnetic rod during the slow descending process of the magnetic rod, so that under the condition that the elution volume is small, the eluent can still cover all the magnetic beads and circulate for many times, and even the magnetic beads with small particle sizes can be effectively adsorbed.       Four-Dimensional Integrated Motion Mode Ensures The Best Blending Effect ■ The four-dimensional integrated motion mode of X/Y/Z motion of the mechanical arm integral module and vibration of the mixing parts ensures stable operation and high precision of the instrument; ■ The instrument has high oscillation frequency and adjustable multi-gear, which is suitable for different reagent integration schemes; ■ The vibration amplitude can be adaptively adjusted according to the solution volume set by the user, thus achieving the best experimental mixing effect. Professional Pollution Control & Safety Guarantee ■ UV sterilization module: It can ensure that the operation in the machine reaches a sterile environment; ■ Anti-aerosol fan: Keep the air in the instrument in circulation to avoid aerosol pollution; ■ Anti-dripping disc: Effectively avoid cross contamination between wells and plates; ■ Closed operation: If the door is opened accidentally, the instrument will automatically pause to ensure safety; ■ Disposable reagent consumables: To protect the safety of laboratory personnel and laboratory environment to the greatest extent. Reasonable Design of The Expandable Throughout The matrix arrangement of double row and four plate positions not only ensures the expandability of the experiment, but also reduces the occupied area of the instrument and effectively uses the space. Under limited conditions, it can be expanded to extract 192 samples at a time, ensuring a ultra-high throughput extraction capability. With double heating modules of lysis/elution, the extraction efficiency can be improved.        Intuitive and User-Friendly Human-Computer Interaction Interface The 10.1-inch touch computer is equipped with Windows system and touch operation, which is simple and easy to use, conforming to the user’s usage habits. The program setting takes full account of the experimental expansibility, multi-parameter free configuration, and large integration and development space. Product Guide for TGuide S96  Features ■ Extremely high throughout: 192 samples can be extracted in a single run. ■ Operation mode: 10.1-inch touch interface (Windows system) ■ Magnetic bead adsorption: Cycle adsorption, recovery efficiency ≥ 98% ■ Movement mode: Four-dimensional integrated movement, confirming the best mixing effect ■ Replaceable modules: A 24-flux modules can be provided, with flexible processing volume ■ Professional contamination prevention: Effective avoidance of cross-contamination between wells and plates

Atụmatụ

Kachasị oke nke ukwuu: Enwere ike ịbịpụta nlele 192 n'otu ọsọ.
Mode Ọnọdụ ọrụ: 10.1-inch touch interface (sistemụ Windows)
Mgbasa ozi bead magnet: Mgbasa okirikiri, arụmọrụ mgbake ≥ 98%
Mode Ọnọdụ ngagharị: ngagharị agbakwunyere akụkụ anọ, na-akwado mmetụta agwakọta kacha mma
Mod Modul nwere ike dochie anya: Enwere ike ịnye modulu 24-flux, yana olu nhazi na-agbanwe agbanwe
Prevention Mgbochi mmetọ ndị ọkachamara: Izere nke ọma n'etiti mmetọ n'etiti olulu mmiri na efere

Enwere ike ịhazi ngwaahịa niile maka ODM/OEM. Maka nkọwa,biko pịa Ọrụ ahaziri (ODM/OEM)


  • Nke gara aga:
  • Osote:

  • product_certificate04 product_certificate01 product_certificate03 product_certificate02
    ×
  • Dee ozi gị ebe a ma zitere anyị ya

    Ngwaahịa ngwaahịa